一、節(jié)點構(gòu)造、構(gòu)件位置、連接錨固方法,應全部符合設(shè)計要求。
1、 The joint structure, component location, connection and anchorage method shall all meet the design requirements.
二、輕質(zhì)復合墻板的各項技術(shù)指標須滿足有關(guān)標準所規(guī)定的要求;膠粘劑的配制原料的質(zhì)量須符合有關(guān)規(guī)定;
2、 The technical indexes of light composite wallboard shall meet the requirements of relevant standards; The quality of raw materials for adhesive preparation shall comply with relevant regulations;
三、增強水泥空心條板其四邊的粘結(jié)必須牢固。
3、 The bonding of four sides of reinforced cement hollow slab must be firm.
四、輕質(zhì)復合墻板所有接縫處的粘結(jié)應牢固,應填塞密實,不應出現(xiàn)干縮裂縫。
4、 The bonding of all joints of light composite wallboard shall be firm, and it shall be filled tightly without shrinkage cracks.
五、吊掛點埋件必須牢固。
5、 The embedded parts of the hanging point must be firm.
六、門窗框與門窗框板之間用電焊連接時,焊縫的長度應大于或等于10mm,焊縫厚度不應小于4mm。焊縫表面平整,無燒傷、凹陷、焊瘤、裂紋、咬邊、氣孔和夾渣等缺陷,其焊點表面應凹進板面3mm。
6、 When the door and window frames and the door and window frame plates are connected by electric welding, the length of the welding seam shall be greater than or equal to 10 mm, and the thickness of the welding seam shall not be less than 4 mm. The weld surface shall be smooth without burn, depression, weld bead, crack, undercut, air hole, slag inclusion and other defects, and the weld surface shall be 3 mm concave into the plate surface.
以上就是輕質(zhì)復合墻板質(zhì)量驗收標準,當然以上的驗收標準只是現(xiàn)在的,以后會根據(jù)實際情況進行更優(yōu)異的改進。
The above is the quality acceptance standard of light composite wallboard, of course, the above acceptance standard is only now, and will be improved according to the actual situation in the future.